The Testo 875-1 features a detector size of 160 x 120 pixels providing 19,200 temperature measurement points and good quality images clearly and precisely. Optional SuperResolution technology improves the image quality by one class, i.e. the resolution of the thermal images is four times higher. With an excellent thermal sensitivity of <80 mK, even small temperature differences are visible. Critical temperature statistics are directly displayed using the automatic Hot-Cold-Spot recognition.
IR RESOLUTION (ARRAY SIZE) | 19,200 (160 x 120) |
THERMAL SENSITIVITY | <0.08°C (80mK) |
FIELD OF VIEW | 32° x 23° / 7" min. focus |
TEMPERATURE RANGE | -4 to 232°F (-20 to 100°C)/ 32 to 536°F (0 to 280°C) |
ACCURACY | ±2% rdg. |
MEASUREMENT MODES | Spot |
FRAME REFRESH | 9 Hz |
THERMAL PALETTES | 4 |
FOCUS | Manual |
DISPLAY SCREEN | 3.5" LCD |
VISUAL CAMERA | No |
DIGITAL ZOOM | No |
IMAGE FUSION | Twin Pix |
PICTURE-IN-PICTURE | Yes |
MEMORY STORAGE | 2GB SD card |
VIDEO OUTPUT | Yes |
INSULATION ALARM | Yes |
COLOUR ALARM | Yes |
1 - Hard shell storage case
1 - 2 GB SD memory card
1 - IRSoft software
1 - Power supply
1 - Battery
The patent-pending SuperResolution technology improves the thermal image quality of your Testo imagers with the included software upgrade. With SuperResolution, images have a higher resolution, and are therefore more detailed.
The important thing is that SuperResolution technology always records genuine temperature measuring values. There are no artificial intermediate values projected! This means that this technology offers the possibility of recording more temperature measuring values without using larger, more expensive detectors.
SuperResolution in Building Thermography
In building thermography, SuperResolution technology is ideally suited to fast and effective detection of building damage. Energy losses in buildings’ heating or air conditioning systems can also be analyzed with the help of the high-resolution thermal images. The high level of detail in the image makes inadequate insulation, resulting heat losses or construction defects clearly visible. Leakages can also be displayed precisely in the thermal image using SuperResolution technology.
SuperResolution in Industrial Thermography
SuperResolution technology also plays an important role in industrial maintenance – above all in the detailed early detection of imminent damage in production-related plant components. In the case of mechanical components too, thermal irregularities (e.g. due to friction or incorrect adjustment) can indicate an elevated level of stress. In the field of research and development, the geometric resolution of the thermal image is of great significance. This is improved by a factor of 1.6 by SuperResolution technology. This means that even smaller objects can be recorded, which enables the measurement of the smallest possible structures.
Click on a category to view a selection of compatible accessories with the Testo 875-1 Thermal Imager, 19 200 Pixels (160 x 120).
IR RESOLUTION (ARRAY SIZE) | 19,200 (160 x 120) |
THERMAL SENSITIVITY | <0.08°C (80mK) |
FIELD OF VIEW | 32° x 23° / 7" min. focus |
TEMPERATURE RANGE | -4 to 232°F (-20 to 100°C)/ 32 to 536°F (0 to 280°C) |
ACCURACY | ±2% rdg. |
MEASUREMENT MODES | Spot |
FRAME REFRESH | 9 Hz |
THERMAL PALETTES | 4 |
FOCUS | Manual |
DISPLAY SCREEN | 3.5" LCD |
VISUAL CAMERA | No |
DIGITAL ZOOM | No |
IMAGE FUSION | Twin Pix |
PICTURE-IN-PICTURE | Yes |
MEMORY STORAGE | 2GB SD card |
VIDEO OUTPUT | Yes |
INSULATION ALARM | Yes |
COLOUR ALARM | Yes |
1 - Hard shell storage case
1 - 2 GB SD memory card
1 - IRSoft software
1 - Power supply
1 - Battery
The patent-pending SuperResolution technology improves the thermal image quality of your Testo imagers with the included software upgrade. With SuperResolution, images have a higher resolution, and are therefore more detailed.
The important thing is that SuperResolution technology always records genuine temperature measuring values. There are no artificial intermediate values projected! This means that this technology offers the possibility of recording more temperature measuring values without using larger, more expensive detectors.
SuperResolution in Building Thermography
In building thermography, SuperResolution technology is ideally suited to fast and effective detection of building damage. Energy losses in buildings’ heating or air conditioning systems can also be analyzed with the help of the high-resolution thermal images. The high level of detail in the image makes inadequate insulation, resulting heat losses or construction defects clearly visible. Leakages can also be displayed precisely in the thermal image using SuperResolution technology.
SuperResolution in Industrial Thermography
SuperResolution technology also plays an important role in industrial maintenance – above all in the detailed early detection of imminent damage in production-related plant components. In the case of mechanical components too, thermal irregularities (e.g. due to friction or incorrect adjustment) can indicate an elevated level of stress. In the field of research and development, the geometric resolution of the thermal image is of great significance. This is improved by a factor of 1.6 by SuperResolution technology. This means that even smaller objects can be recorded, which enables the measurement of the smallest possible structures.
Click on a category to view a selection of compatible accessories with the Testo 875-1 Thermal Imager, 19 200 Pixels (160 x 120).