Commercial/Industrial Combustion & NOx kit measures O2, CO (to 30,000ppm), temperature, pressure and other required combustion efficiency parameters. This model includes Bluetooth.
Commercial/Industrial Combustion & NOx kit measures O2, CO (to 30,000ppm), temperature, pressure and other required combustion efficiency parameters. This model includes Bluetooth.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
This model includes Bluetooth.
For commercial and industrial boiler combustion analysis, the Testo 330-2G LL Kit 2 combustion analyzer is properly outfitted NO sensor to calculate NOX, high range CO, sensor protection, large memory for maintaining service records, and on-site printing capability. The Testo 330-2G LL combustion analyzer has the longest sensor warranty on the market - 4 years!. Rugged construction and high quality sensors provide years of reliability and very low cost-of-ownership.
Features
Differential Pressure | |
---|---|
Measuring Range | 0 to 300 inH2O |
Accuracy | ±0.5 inH2O (0.0 to 50.0 inH2O) ±1% of rdg. (50.1 to 100.0 inH2O) ±1.5 % of rdg. (remaining range) |
Resolution | 0.1 inH2O |
CO Low | |
Measuring Range | 0 to 500 ppm |
Accuracy | ±2 ppm (0.0 to 40.0 ppm) ±5% of rdg. (remaining range) |
Resolution | 0.1 ppm |
NO Measurement | |
Measuring Range | 0 to 3000 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of rdg. (101 to 2000 ppm) ±10% of rdg. (2001 to 3000 ppm) |
Resolution | 1 ppm |
O2 Measurement | |
Measuring Range | 0 to 21 Vol. % |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol. % |
Exhaust Gas Measurement | |
Measuring Range | 0 to 99.9% |
Resolution | 0.1% |
Draft Measurements | |
Measuring Range | -9.99 to +40 inH2O |
Accuracy | ±0.02 inH2O or ±5% of rdg. (-0.50 to +0.60 inH2O) ±0.03 inH2O (+0.61 to +3.00 inH2O) ±1.5% of rdg. (+3.01 to +40.00 inH2O) |
Resolution | 0.01 inH2O |
CO Measurement (Electrochemical) | |
Measuring Range | 0 to 8000 ppm |
Accuracy | ±10 ppm or ±10% of rdg. (0 to 200 ppm) ±20 ppm or ±5% of rdg. (201 to 2000 ppm) ±10% of rdg. (2001 to 8000 ppm) |
Resolution | 1 ppm |
CO2 | |
Measuring Range | 0 to 1 Vol. % 0 to 10.000 ppm |
Accuracy | ±(50 ppm ±2% of rdg.) (0 to 5000 ppm) |
Reaction time | Approx. 35 sec. |
CO | |
Measuring Range | 0 to 500 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of rdg. (>100 ppm) |
Resolution | 1 ppm |
Reaction time | Approx. 35 sec. |
Efficiency Measurement (ETA) | |
Measuring Range | 0 to 120% |
Resolution | 0.1% |
Type K | |
Measuring Range | -40 to 1200 °C |
Accuracy (relative) | ±0,5 °C (0.0 to +100.0 °C) ±0,5 % of rdg. (remaining range) |
Resolution | 0.1 °C (-40 to 999,9 °C) 1 °C (remaining range) |
CO2 - Determination | |
Measuring Range | 0 to CO2 max |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol.% |
Reaction time | < 40 sec. |
General Specifications | |
Memory | 500.000 values |
Storage Temperature | -20 to 50 °C |
Operating Temperature | -5 to +45 °C |
Dimensions | 270 x 90 x 65 mm |
Click on a category to view a selection of compatible accessories with the Testo 330-2G LL Kit #2 Combustion Analyzer with NOX and Hi-range CO with Bluetooth.
Differential Pressure | |
---|---|
Measuring Range | 0 to 300 inH2O |
Accuracy | ±0.5 inH2O (0.0 to 50.0 inH2O) ±1% of rdg. (50.1 to 100.0 inH2O) ±1.5 % of rdg. (remaining range) |
Resolution | 0.1 inH2O |
CO Low | |
Measuring Range | 0 to 500 ppm |
Accuracy | ±2 ppm (0.0 to 40.0 ppm) ±5% of rdg. (remaining range) |
Resolution | 0.1 ppm |
NO Measurement | |
Measuring Range | 0 to 3000 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of rdg. (101 to 2000 ppm) ±10% of rdg. (2001 to 3000 ppm) |
Resolution | 1 ppm |
O2 Measurement | |
Measuring Range | 0 to 21 Vol. % |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol. % |
Exhaust Gas Measurement | |
Measuring Range | 0 to 99.9% |
Resolution | 0.1% |
Draft Measurements | |
Measuring Range | -9.99 to +40 inH2O |
Accuracy | ±0.02 inH2O or ±5% of rdg. (-0.50 to +0.60 inH2O) ±0.03 inH2O (+0.61 to +3.00 inH2O) ±1.5% of rdg. (+3.01 to +40.00 inH2O) |
Resolution | 0.01 inH2O |
CO Measurement (Electrochemical) | |
Measuring Range | 0 to 8000 ppm |
Accuracy | ±10 ppm or ±10% of rdg. (0 to 200 ppm) ±20 ppm or ±5% of rdg. (201 to 2000 ppm) ±10% of rdg. (2001 to 8000 ppm) |
Resolution | 1 ppm |
CO2 | |
Measuring Range | 0 to 1 Vol. % 0 to 10.000 ppm |
Accuracy | ±(50 ppm ±2% of rdg.) (0 to 5000 ppm) |
Reaction time | Approx. 35 sec. |
CO | |
Measuring Range | 0 to 500 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of rdg. (>100 ppm) |
Resolution | 1 ppm |
Reaction time | Approx. 35 sec. |
Efficiency Measurement (ETA) | |
Measuring Range | 0 to 120% |
Resolution | 0.1% |
Type K | |
Measuring Range | -40 to 1200 °C |
Accuracy (relative) | ±0,5 °C (0.0 to +100.0 °C) ±0,5 % of rdg. (remaining range) |
Resolution | 0.1 °C (-40 to 999,9 °C) 1 °C (remaining range) |
CO2 - Determination | |
Measuring Range | 0 to CO2 max |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol.% |
Reaction time | < 40 sec. |
General Specifications | |
Memory | 500.000 values |
Storage Temperature | -20 to 50 °C |
Operating Temperature | -5 to +45 °C |
Dimensions | 270 x 90 x 65 mm |
Click on a category to view a selection of compatible accessories with the Testo 330-2G LL Kit #2 Combustion Analyzer with NOX and Hi-range CO with Bluetooth.